Model | HY-600 |
Rated Output | 600W |
Peak Output | 750W |
Controller Output Voltage(V) | DC 24/48 |
Start-up Speed | 2m/s or 4.5mph |
Cut-in Speed | 2.5m/s or 5.6mph |
Rated Rotor Speed(RPM) | 750 |
Rated Wind Speed(m/s) | 12m/s or 26.8mph |
System average Cp. | ≥0.36 |
Rated Charging Current(A) | 25/12.5 |
Noise Level | <20dB (5m behind turbine @ 5m/s gusting) |
KWH/month(monthly avg.V=5,5m/s) | 91 |
Working Tem. Range ℃ | From -40℃ to 60℃ |
Survival Max. Wind | 50m/s or 110mph |
Over-speed control | Electromagnetic & blade aerodynamic braking |
Number of Blades | 5 |
Rotor Diameter(m) | 1.75 |
Swept Area(m²) | 2.4 |
Blade Material | Reinforced glass-fiber nylon |
Generator Type | Brushless 3-phase PMA(Neodymium Magnet) |
Generator Material | Aluminum alloy body &stainless steel rotor |
Net Weight | 25 KG |
Tower Connection | Flange connection or bolt-on clamp |
Warranty(years) | 3 |
Certificate | ISO 9001:2008,CE,RoHS,ETL |
Model | HY-T2-WSII-06-NNHN-1 | HY-T4-WS-06-NNHN-1 |
Battery parameters |
Applied battery voltage | 24V 48V |
Battery protect method | Reverse connection protection (do not burn any components, with voice prompt); over voltage protection, under voltage protection (for street light and such kind of load) |
Voltage at the over voltage protection point | 29.0V±0.2V | 58.0V±0.3V |
Voltage at the over voltage recovery point | 27.5V±0.2V | 55.0V±0.3V |
Voltage at the under voltage protection point | 21.0V±0.2V | 42.0V±0.3V |
Voltage at the under voltage recovery point | 23.0V±0.2V | 46.0V±0.3V |
Battery temperature compensation | 5mv/℃/2V (settable) (optional component) |
Wind turbines input parameters |
Rated power of applied Wind turbines | 600W/24V | 600W/48V |
Rated power of the terminal | 30A dc (after rectification) | 15A dc (after rectification) |
Max. input current of the terminal | 40A dc (after rectification) | 20A dc (after rectification) |
The default speed of the Wind turbines generation with limited speed | 500 Rpm (settable) |
The default current of the Wind turbines generation with limited current | 30A (settable) | 15A (settable) |
Wind turbines protection method | over rev protection, over current protection, induction lightening protection |
Unloading method | PWM stepless high-frequency soft unloading (built-in) |
MPPT function | Boost MPPT model ( automatic tracking or 5 segments curve tracking) |
Input current of MPPT channel | 12A |
PV input parameters |
| | |
Rated input current of terminal | 15A(standard) 30A(optional) |
Charging voltage drop | <0.2V |
PV protection methods | Reverse connection protection (voice prompt) |
Unloading method | Open circuit unloading |
Discharge the output port parameters |
output | 2 outputs |
Current of each output | 12A |
Output protection methods | Over current protection (15A/30sec. 18A/0.4sec.), short-circuit protection (current > 150A) |
Output control methods | light control, time control, reverse output, PWM output (250HZ, only the 2nd output has it) |
Working temperature / humidity range (environment) | -40~+80℃/20~85%RH(non condensing) |
Protection grade | IP41 |
Controller size (L*W*H) | 175mm*148mm *84mm |
Net weight | 1.8KG |
| | | | |